<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-13 10-13-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -10 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 10060 25,5368
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,2 dBr 7,11 dBr 7,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 10:13, 13.03.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (56 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 25,5368 Acquired: 2025/03/13 10:12:39 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,6 dBr MIN: 6,2 dBr AVE: 7,11 dBr % above 10,0 dBr: 0,0 Last value: 6,5 dBr (2025/03/13 10:12:39) Station: 96.90 MHz, signal: 4/5 (55 dBuV) 10:06 10:07 10:08 10:09 10:10 10:11 10:12 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality